Header menu link for other important links
X
Reduced graphene oxide-yttria nanocomposite modified electrode for enhancing the sensitivity of electrochemical genosensor
, Thulasi Radhakrishnan, P. Shihabudeen K., N. Sandhyarani
Published in Elsevier Ltd
2016
PMID: 27153526
Volume: 83
   
Pages: 361 - 367
Abstract
Reduced graphene oxide-yttria nanocomposite (rGO:Y) is applied as electrochemical genosensor platform for ultrahigh sensitive detection of breast cancer 1 (BRCA1) gene for the first time. The sensor is based on the sandwich assay in which gold nanoparticle cluster labeled reporter DNA hybridize to the target DNA. Glassy carbon electrode modified with rGO-yttria serves as the immobilization platform for capture probe DNA. The sensor exhibited a fine capability of sensing BRCA1 gene with linear range of 10 attomolar (aM) to 1 nanomolar (nM) and a detection limit of 5.95 attomolar. The minimum distinguishable response concentration is down to the attomolar level with a high sensitivity and selectivity. We demonstrated that the use of rGO:Y modified electrode along with gold nanoparticle cluster (AuNPC) label leads to the highly sensitive electrochemical detection of BRCA1 gene.
About the journal
JournalData powered by TypesetBiosensors and Bioelectronics
PublisherData powered by TypesetElsevier Ltd
ISSN18734235
Open AccessNo